With ambition, courage and hard work, we are committed to realizing the dream of 'building a leading brand in the Plastic Volumetric Water Meter, Plastic Single Jet Water Meter, Single-jet Cold Water Meter industry'. We warmly welcome you to contact us to begin discussions on how we can bring this into being. Our corporate personality is self-improvement, self-confidence and autonomy. To meet the requirements of specific customers for each bit more perfect service and stable quality merchandise. Our company follows the business philosophy of 'quality for survival, technology for development, market-oriented and service-oriented'.
Woltman Type Water Meter Class B (40mm-600mm)
Application
For measurement of high flows of hot potable water passing through the pipelines in sizes of 40mm to 600mm.
Features
*Magnetic drive, lower transmission resistance.
*Sealed dry dial register ensures clear reading.
*The measuring mechanism can be removable from the body for checking, maintaining and replacing, and the body needn't be dismantled from the pipeline.
*Inter-exchangeable parts.
*Low pressure loss. Long working life.
*Can be equipped with reed switch (register can't rotate).
Standard Compliance
Technical data conforms to ISO 4064 Class B, R50, R63 and R80 standard
Working Conditions
Water temperature: ≤50ºC for cold water meter
Water temperature: ≤90ºC for hot water meter
Water pressure: ≤1MPa or 1.6MPa or 4.0 MPa optional (10bar or 16bar r 40 bar optional)
Installation requirements
*The meter can be installed in horizontal, vertical or inclined position.
*A horizontal position with the register face upwards is recommended.
*Pipeline must be flushed before installation.
*The meter should be constantly full of water during operation.
Maximum Permissible Error
In the lower zone from Qmin(Q1) inclusive up to but excluding Qt (Q2) is ±5%.
In the upper zone from Qt(Q2) inclusive up to and including Qmax(Q4) is ±2%(cold water meter).
In the upper zone from Qt(Q2) inclusive up to and including Qmax (Q4) is ±3% (hot water meter). 

MAIN TECHNICAL DATA According to ISO4064 :2003 (Old Standard)
Meter Size | Measuring | Max Flow | Nominal Flow | Transitional Flow | Min Flow | Min Reading | Max Reading | ||
mm | class | m³/h | m³ | ||||||
40 | B | 20 | 10 | 0.8 | 0.2 | 0.0002 | 999999 | ||
50 | B | 30 | 15 | 3 | 0.45 | 0.0002 | 999999 | ||
65 | B | 50 | 25 | 5 | 0.75 | 0.0002 | 999999 | ||
80 | B | 80 | 40 | 8 | 1.2 | 0.002 | 999999 | ||
100 | B | 120 | 60 | 12 | 1.8 | 0.002 | 999999 | ||
125 | B | 200 | 100 | 20 | 3 | 0.002 | 999999 | ||
150 | B | 300 | 150 | 30 | 4.5 | 0.002 | 999999 | ||
200 | B | 500 | 250 | 50 | 7.5 | 0.002 | 999999 | ||
250 | B | 800 | 400 | 80 | 12 | 0.002 | 999999 | ||
300 | B | 1200 | 600 | 120 | 18 | 0.02 | 9999999 | ||
350 | B | 1600 | 800 | 160 | 24 | 0.02 | 999999999 | ||
400 | B | 2000 | 1000 | 200 | 30 | 0.02 | 999999999 | ||
500 | B | 3000 | 1500 | 300 | 45 | 0.02 | 999999999 | ||
600 | B | 6000 | 3000 | 600 | 90 | 0.02 | 999999999 | ||
MAIN TECHNICAL DATA According to ISO4064:2005 (New Standard)
Meter Size | Measuring | Q4 | Q3 | Q2 | Q1 | Min Reading | Max Reading |
mm | R | m³/h | m³ | ||||
40 | 63 | 20 | 16 | 0.41 | 0.25 | 0.0002 | 999999 |
50 | 63 | 31.25 | 25 | 0.63 | 0.40 | 0.0002 | 999999 |
65 | 80 | 50 | 40 | 0.80 | 0.50 | 0.0002 | 999999 |
80 | 80 | 78.7 | 63 | 1.26 | 0.79 | 0.002 | 999999 |
100 | 80 | 125 | 100 | 2.00 | 1.25 | 0.002 | 999999 |
125 | 80 | 200 | 160 | 3.20 | 2.00 | 0.002 | 999999 |
150 | 80 | 312.5 | 250 | 5.00 | 3.13 | 0.002 | 999999 |
200 | 63 | 500 | 400 | 10.16 | 6.35 | 0.002 | 999999 |
250 | 50 | 787 | 630 | 20.16 | 12.60 | 0.002 | 999999 |
300 | 50 | 1250 | 1000 | 32 | 20 | 0.02 | 9999999 |
350 | 50 | 2000 | 1600 | 51.2 | 32 | 0.02 | 999999999 |
400 | 50 | 3125 | 1600 | 51.2 | 32 | 0.02 | 999999999 |
500 | 50 | 5000 | 2500 | 80 | 50 | 0.02 | 999999999 |
600 | 50 | 7870 | 4000 | 128 | 80 | 0.02 | 999999999 |
Dimensions and Weight

Meter size | Length L | Width W | Height H | Connecting thread | ||
mm | mm | D | Bolt circle Dia D1 | Connecting bolt | ||
40 | 200 | 256 | 400 | 165 | 125 | 4xM16 |
50 | 200 | 256 | 400 | 165 | 125 | 4xM16 |
65 | 200 | 256 | 400 | 185 | 145 | 4xM16 |
80 | 225 | 276 | 400 | 200 | 160 | 8xM16 |
100 | 250 | 286 | 400 | 220 | 180 | 8xM16 |
125 | 250 | 301 | 400 | 250 | 210 | 8xM16 |
150 | 300 | 346 | 500 | 285 | 240 | 8xM20 |
200 | 350 | 373 | 500 | 340 | 295 | 8xM20 |
250 | 450 | 493 | 730 | 395 | 350 | 12xM20 |
300 | 500 | 516 | 730 | 445 | 400 | 12xM20 |
350 | 500 | 560 | 730 | 520 | 470 | 12xM21 |
400 | 600 | 631 | 830 | 565 | 515 | 16xM24 |
500 | 800 | 785 | 930 | 715 | 650 | 20xM30 |
600 | 1000 | 865 | 1030 | 840 | 770 | 20xM33 |
We intention at becoming one among your most trusted partners and earning your fulfillment for Ws Dn50~150e Removable Woltman Vertical Water Meter. We'll continue to develop, to deliver the high-quality items and services, and promote lasting cooperation with our customers, common development and create a better future. The market can have no enterprise, but the enterprise cannot have the market, and the market comes from the favor of customers.
Hot Tags: Woltman Type Water Meter, China, Manufacturers, Suppliers, Factory, Brass Single Jet Water Meter, Wet Type Water Meter, Woltman Water Meter, Plastic Water Meter Box Small, Plastic Single Jet Water Meter, Removable Element Woltman Cold Water Meter