All of us adhere to the business philosophy of unity, perseverance, and mutual achievement, and insist on low-cost and high efficiency as our Hot Removable Woltman Water Meter, Local Instrument Water Meter, Plastic Volumetric Water Meter's design direction. Our tenet is 'professional' and 'proficient', and we will provide you with safe, reliable and complete pre-sales and after-sales services. Welcome to call or write to us for consultation. With the continuous development of economy and technology, we will continue to make progress, launch more high-quality products, and continuously improve the after-sales service system to provide customers with better services. Relying on superior quality and excellent post-sales, our products sell well all over the world. Strive for the development and success of customers, let us work together to create a better future.
Electronic Water Meter

WMD15 to WMD50 is a complete electronic water meters without registers, measures cold (hot) potable water for residential application in sizes 15mm to 50mm. It is wiht digital reading.
Features:
Adopting the advanced technology of data coding and verification, with high communication reliability
Meeting EMC/ESD/EMI, the design requirements of electromagnetic compatibility for the electronic products, reaching the industrial leading level.
Supper low power consumption design, no need of maintenance for the circuit.
Water proof grade as IP 68, suitable for different complicated environment.
Anti-drop and anti reverse flow.
High sensitive and high endurance structure, with long lifetime.
Anti-magnetic.
Designed as the function of flow meter.
Standard Compliance
Technical data conforms to ISO 4064 Class B, Class C, R80, R100, R125 or R160 standard for horizontal installation.
Optional Features
*Several lengths and connections available on request
*Non return Valve
*Pulse output option: reed switch; hall or non-magnetic metal plate.
*Meter body: Brass, plastic, iron and stainless steel for selecting.
Working Conditions
Water temperature: ≤50ºC for cold water meter Water temperature: ≤90ºC for hot water meter Water pressure: ≤1MPa or 1.6MPa optional (10bar or 16bar optional)
Installation requirements
*The meter should be installed in horizontal position with the direction of the flow as indicated by the arrow cast in the meter body with the register face upwards.
*Pipeline must be flushed before installation.
*The meter should be constantly full of water during operation.
Maximum Permissible Error
In the lower zone from Qmin(Q1) inclusive up to but excluding Qt (Q2) is ±5%.
In the upper zone from Qt(Q2) inclusive up to and including Qmax(Q4) is ±2%(cold water meter).
In the upper zone from Qt(Q2) inclusive up to and including Qmax (Q4) is ±3% (hot water meter). 
Accessories
Each water meter has one set couplings optional: 2pcs tube, 2pcs nut and 2pcs gasket
MAIN TECHNICAL DATA According to ISO4064 :2003 (Old Standard)
| Size | Inch | Class | Qmax | Qn | Qt | Qmin | Min reading | Max reading |
| Maximum flow | Nominal flow | Transitional flow | Min flow | |||||
| DN(mm) | m³/h | L/h | m³ | |||||
| 15 | 1/2" | B | 3 | 1.5 | 120 | 30 | 0.00005 | 99999 |
| C | 22.5 | 15 | ||||||
| 20 | 3/4" | B | 5 | 2.5 | 200 | 50 | 0.00005 | 99999 |
| C | 37.5 | 25 | ||||||
| 25 | 1" | B | 7 | 3.5 | 280 | 70 | 0.00005 | 99999 |
| C | 52.5 | 35 | ||||||
| 32 | 11/4" | B | 12 | 6 | 480 | 120 | 0.00005 | 99999 |
| C | 90 | 60 | ||||||
| 40 | 11/2" | B | 20 | 10 | 800 | 200 | 0.00005 | 99999 |
| C | 150 | 100 | ||||||
| 50 | 2" | B | 30 | 15 | 3000 | 450 | 0.00005 | 99999 |
| C | 225 | 90 | ||||||
MAIN TECHNICAL DATA According to ISO4064:2005 (New Standard)
| DN | Mm | 15 | 20 | 25 | 32 | 40 | 50 |
| SIZE | Inch | 1/2" | 3/4" | 1" | 11/4" | 11/2" | 2" |
| Q4(m³/h) | 3.125 | 5 | 7.875 | 12.5 | 20 | 31.25 | |
| Q3(m³/h) | 2.5 | 4 | 6.3 | 10 | 16 | 25 | |
| R80 | Q2(L/h) | 50 | 80 | 126 | 200 | 320 | 500 |
| Q1(L/h) | 31.25 | 50 | 78.75 | 125 | 200 | 312.5 | |
| R100 | Q2(L/h) | 40 | 64 | 100.8 | 160 | 256 | 400 |
| Q1(L/h) | 25 | 40 | 63 | 100 | 160 | 250 | |
| R125 | Q2(L/h) | 32 | 51.2 | 80.64 | 128 | 204.8 | 320 |
| Q1(L/h) | 20 | 32 | 50.4 | 80 | 128 | 200 | |
| R160 | Q2(L/h) | 25 | 40 | 63 | 100 | 160 | 250 |
| Q1(L/h) | 15.62 | 25 | 39.37 | 62.5 | 100 | 156.2 | |
| Min reading(m³) | 0.00005 | 0.00005 | 0.00005 | 0.00005 | 0.00005 | 0.00005 | |
| Max reading(m³) | 99999 | 99999 | 99999 | 99999 | 99999 | 99999 | |
| Max pressure(MAP) | 16 | 16 | 16 | 16 | 16 | 16 | |
| Max loss(ΔP) | 63 | 63 | 63 | 63 | 63 | 63 | |
| Max temperature | T50 | T50 | T50 | T50 | T50 | T50 | |
| Pulse output option | reed switch | Vmax=24V, Imax=100mA, Pmax=2W | |||||
| hall | / | ||||||
| non-magnetic metal plate | / | ||||||
Dimensions and Weight

| Meter Size | Length (L) | Width (B) | Height (H) | Connecting Thread |
| mm | mm | D | ||
| 15 | 165/190 | 98 | 104 | G 3/4B |
| 20 | 190/195 | 98 | 106 | G 1B |
| 25 | 260/225 | 103 | 115 | G1 1/4B |
| 32 | 260/230 | 103 | 115 | G1 1/2B |
| 40 | 300/245 | 124 | 153 | G 2'B |
| 50 | 300 | 124 | 153 | G2 1/2 B |
| 280 | 165 | 175 | Flange connecting GB 4216.4 | |





All Household Meat Water Oil Cooking Electronic Probe Food Oven Thermometer of our company adopt the industry standard. Our products are exported to overseas and enjoy a good reputation in many overseas markets. We are backed with a robust infrastructural facility that enables us to manufacture, store, quality check and dispatch our products worldwide. Our company has always adhered to the concept of 'people-oriented, honest management', and has trained a large number of experienced and skilled personnel. Products have undergone strict inspection before leaving the factory to ensure reliable quality.
Hot Tags: Electronic Water Meter China, Manufacturers, Suppliers, Factory, Single Jet Water Meter Liquid Sealed, Plastic Single Jet Water Meter, R160 Water Meter, Remote Water Meter, Class C Water Meter, Local Instrument Water Meter