Digital Bulk PA6+25%GF Plastic Flow Rotary Single-Stream Water Meter with ISO for Industrial

Digital Bulk PA6+25%GF Plastic Flow Rotary Single-Stream Water Meter with ISO for Industrial

Photoelectric Direct Reading Remote Control Digital Water Meter Horizontal Type R160 LXZ2 is a horizontal type remote control smart water meter, measuring the cold potable water for residential application in sizes 15mm-40mm for cold water. Features * Adopting M-BUS or RS485 communication mode....
Send Inquiry
Description

Our company has very rich practical experience in the field of Single Jet Water Meter Liquid Sealed, Irrigation Water Meter, Stainless Steel Dringking Water Meter, relying on a perfect management system and after-sales service, and strive to make our customers satisfied with our products. We use high-quality raw materials, strictly controlling all production links, and setting up multiple inspection points on the production line to ensure product quality. We create a win-win development future with our customers with exquisite craftsmanship, strict quality management, and thoughtful service system. The company is committed to the development of new products in the market and pursues the principle of improving product quality and treating customers wholeheartedly. Our company pays attention to the cultivation and care of talents.

Photoelectric Direct Reading Remote Control Digital Water Meter Horizontal Type R160 Photoelectric Direct Reading Remote Control Digital Water Meter Horizontal Type R160

LXZ2 is a horizontal type remote control smart water meter, measuring the cold potable water for residential application in sizes 15mm-40mm for cold water. It's the most accurate water meter in a long-term run.


Features

* Adopting M-BUS or RS485 communication mode.

* Electronic parts are separately sealed, and the water proof can be IP68.

* Highest accuracy, lowest error, low starting flow rate.

* Multi jet dry type water meter.

* Magnetic drive, lower transmission resistance, frog-resistant. * Magnetic shield, for external magnetic field protection

* Low power consumption.

* Being stable and reliable by the "position identification" characteristics of photoelectric and microelectronic technology.

* Automatic reading and management.

* Each meter has an unique location number, easy wire construction.


Standard Compliance

Technical data conforms to ISO 4064 Class B, Class C, R80, R100, R125 or R160 standard for horizontal installation.


Optional Features

* Meter body: Brass and iron for selecting.

* Communication interface mode: RS485 interface or MBUS interface (optional)

* Communication transmission rate: 1200bps, 2400bps, 4800bps or 9600bps (optional)

*Communication specification: CJ/T188-2004 agreement, DL/T645-2007 or MODBUS Agreement (optional), or a special agreement to be made to order


.Working Conditions

*Power Supply: DC 9-24V (RS485 interface) and DC24-42V(MBUS interface);

* Humidity: 0~95% RH *The distance between data collector and meter: ≤300m;

* Power consumption: ≤1uA (Static Working Current); ≤12uA (instant current during remote reading)

* Water temperature: ≤50ºC for cold water meter

* Water temperature: ≤90ºC for hot water meter

* Water pressure: ≤1MPa or 1.6MPa optional (10bar or 16bar optional) 


Installation requirements

*The meter should be installed in vertical position with the direction of the flow as indicated by the arrow cast in the meter body with the register face upwards. *Pipeline must be flushed before installation. *The meter should be constantly full of water during operation.


Maximum Permissible Error

In the lower zone from Qmin(Q1) inclusive up to but excluding Qt (Q2) is ±5%. In the upper zone from Qt(Q2) inclusive up to and including Qmax(Q4) is ±2%(cold water meter).

In the upper zone from Qt(Q2) inclusive up to and including Qmax (Q4) is ±3% (hot water meter). 

Accessories

Each water meter has one set couplings optional: 2pcs tube, 2pcs nut and 2pcs gasket.

MAIN TECHNICAL DATA According to ISO4064 :2003 (Old Standard)

SizeInchClassQmaxQnQtQminMin readingMax reading
Maximum flowNominal flowTransitional flowMin flow
DN(mm)m³/hL/h
151/2"B31.5120300.0000599999
C22.515
203/4"B52.5200500.0000599999
C37.525
251"B73.5280700.0000599999
C52.535
3211/4"B1264801200.0000599999
C9060
4011/2"B20108002000.0000599999
C150100

MAIN TECHNICAL DATA According to ISO4064:2014 (New Standard)

DNMm1520253240
SIZEInch1/2"3/4"1"11/4"11/2"
Q4(m³/h)3.12557.87512.520
Q3(m³/h)2.546.31016
R80Q2(L/h)5080126200320
Q1(L/h)31.255078.75125200
R100Q2(L/h)4064100.8160256
Q1(L/h)254063100160
R125Q2(L/h)3251.280.64128204.8
Q1(L/h)203250.480128
R160Q2(L/h)254063100160
Q1(L/h)15.622539.3762.5100
Min reading(m³)0.000050.000050.000050.000050.00005
Max reading(m³)9999999999999999999999999
Max pressure(MAP)1616161616
Max loss(ΔP)6363636363
Max temperatureT50T50T50T50T50

Dimensions and Weight

Photoelectric Direct Reading Remote Control Digital Water Meter Horizontal Type R160

Meter SizeL1L2L3HWD
mm
DN151652551411887G ¾″B
DN201952951611887G 1″B
DN252253452213092G1 1/4″B
DN322303502213592G1 1/2″B
DN4024538027188116G 2″B


The very rich projects management experiences and one to one service model make the high importance of business communication and our easy understanding of your expectations for Digital Bulk PA6+25%GF Plastic Flow Rotary Single-Stream Water Meter with ISO for Industrial. Our company attaches great importance to employee knowledge training and quality improvement. We have paid attention to product quality for many years, and actively adopted domestic and foreign advanced technology and scientific management to ensure product quality.